Model
|
HTE-100kW-215kWh_Y
|
|
Battery system parameters
|
||
Battery Type
|
LFP,3.2V280Ah
|
|
Battery Module
|
48S1P/153.6V280Ah,43kWh
|
|
Number of Battery Modules
|
5 PCs
|
|
Rated Capacity
|
215kWh
|
|
Rated Voltage
|
768V
|
|
Voltage Range
|
696.0-840.0V(Cell:2.9-3.5Vdc)
|
|
Charge/discharge ratio
|
≤0.5C
|
|
Depth of discharge
|
95% of the time
|
|
Communication Interface
|
RS485/Ethernet/CAN
|
|
Cooling method
|
Liquid Cooling
|
|
Fire-fighting system
|
5-in-1 detector + fire mainframe + Heptafluoropropane/Perfluorohexanone fire suppressor (optional)
|
|
PCS Parameters
|
||
Rated power
|
100kVA
|
|
AC Current Harmonics
|
≤3% (at rated power)
|
|
DC component
|
≤1% (at rated power)
|
|
Rated grid voltage
|
400V
|
|
Grid voltage range
|
340-440V
|
|
Rated grid frequency
|
50/60Hz
|
|
Grid frequency range
|
±10%Hz
|
|
Isolation method
|
No
|
|
Communication interface
|
RS485/Ethernet/CAN
|
|
Communication protocol
|
ModbusRTU,ModbusTCP
|
|
System Parameter
|
||
Installation position
|
Outdoor installation
|
|
Protection grade
|
IP55
|
|
Anti-corrosion grade
|
C5
|
|
Operating humidity range
|
0~95% (non-condensing)
|
|
Operating temperature range
|
-30° C to +50° C
|
|
Maximum working altitude
|
5000m(>3000m derating)
|
|
Dimension(W*D*H)
|
1450*1360*2150 mm
|
|
Weight
|
3500kg
|